Armstrong Vortex Air Separators
- Applications-Air removal from hydronic and HVAC systems – air can get trapped during initial fill, during routine equipment maintenance (including pressure upkeep), and due to the use of cooling towers.
- Description-The Armstrong vortex air separators create a vortex or whirlpool action, sending the heavier air-free water to the outer portion of the tank, and allowing the lighter air-entrained water mixture to move into the lower-velocity center. At the center of the vortex the air is released from the water, forms bubbles and exits through an air vent or compression tank installed above it.
- Materials (MOC)-Cast iron or fabricated steel (shell), stainless steel mesh (strainer)
Description
Benefits & Features
Low installed cost
- Space saving design
Improved system efficiency and operating economy
- Effective air removal right at system start-up.
- Increased heat transfer efficiencies in boilers, fan coils and chillers, for lasting energy savings.
- Fewer ‘air lock’ incidences for increased pumping efficiency.
- Less corrosion and erosion, extending service intervals and overall system life.
- Reduced system noises.
Related products
Armstrong 4280 Motor Mounted Pumps
- Applications-HVAC-system pumping; light industrial / process pumping.
- Description-The Armstrong 4280 horizontal end-suction pumps are equipped with close-coupled motors to minimize footprint requirements.
- Materials(MOC)-Cast iron, ductile iron, or bronze casing, Cast iron or bronze impeller.
- Configuration-Inside single-spring mechanical seal
- Performance range-Up to 2,000 USgpm (125 L/s) flow; up to 400 f (120 m)
- Temperature-250°F (121°C)
- Power Range-0.33 hp to 60 hp (0.25 kW to 45 kW)
- Size-1" to 6” (25 mm to 150 mm)
Armstrong 4380 vertical in-line pumps
- Applications-HVAC-system pumping; light industrial/ process pumping. (water or glycol based)
- Description-The Armstrong 4380 pipe-mounted pumps are designed for space-saving installation and long service life.
- Materials(MOC)-Cast iron or ductile iron casing, Silicon sintered carbide mechanical seal, Cast iron or bronze impeller.
- Configuration-Inside single-spring mechanical seal.
- Performance range-Up to 2,500 USgpm (160 L/s) flow; up to 300 ft (90 m) head
- Temperature-250°F (121°C)
- Power Range-0.33 hp to 60 hp (0.25 kW to 45 kW)
- Size-1.5″ to 8″ (40 mm to 200 mm)
Armstrong Design Envelope 6800 Vertical Multistage Boosters
- Applications-New and retrofit water boosting installations in mid to large size residential, commercial, or industrial settings (such as apartment buildings, office towers, hospitals, hotels, schools, water treatment plants, factories, etc.)
- Description-The Armstrong Design Envelope 6800 Boosters are fully assembled, programmed, integrated and factory-tested turn-key booster systems. They are equipped with vertical multistage pumps and come in arrangements of 2 to 5 pumps. The integrated controls allow for superior performance and energy efficiency across broad operating envelopes. Most suitable for applications where energy consumption and low maintenance are critical, installation space comes at a premium, and occupant comfort is a high priority.
- Materials (MOC)-Piping: stainless steel 304
- Configuration-The 6800 Booster range offers enhanced features, such as improved touchscreens, more performance envelopes, an easy-to-use selection software, and onboard energy and flow readings both present and historic. For the full improved feature set please refer to the Solution Outline for this product.
- Performance range-Up to 2000 USgpm (450 m3/hr) flow; up to 370 psi (22 bar) pressure
- Power Range-Up to 250 hp (up to 185 kW)
Armstrong Design Envelope 9521 Integrated Plant Control System (IPC 9521)
- Applications-Automated chiller plant control for optimizing variable primary flow water-cooled chiller plants. The 9521 IPC works in a variable primary configuration and keeps the entire plant including water-cooled chillers, cooling towers, chilled water and condenser pumps running smoothly.
- Description-The Armstrong Integrated Water-Cooled Chiller Plant Control System (IPC) boosts energy efficiencies of new and existing chiller plant installations to leading class levels. The IPC 9521 works with all variable primary configurations, keeping the entire plant – including water-cooled chillers, cooling towers, chilled water and condenser pumps – running at optimum performance and occupant comfort.
- Configuration-Integrates with all brands of chillers, pumps, and automation systems. Installs directly with chiller plant equipment. If preferred, the IPC connects seamlessly with any central building automation system (BAS) maintaining full control of the chilled water plant through the BAS
- Performance range-Controls up to five chillers, five cooling towers and five pumps. No limitations in plant size and cooling capacity.
- Power Range-No limitations in plant cooling capacity
Armstrong Design Envelope Chilled-Water Integrated Plant Package
- Applications-Commercial and industrial chilled-water cooling systems.
- Description-The Armstrong Chilled-Water Integrated Plant Package combines all the equipment needed to deliver chilled water to medium to large size buildings at superior energy efficiency. The factory-assembled plant includes pumps, integrated controls, water-cooled chillers and the requisite instrumentation, valves and sensors. IPP complies with all ASHRAE 189.1 requirements and exceeds ASHRAE 90.1.
- Configuration-Variable primary with variable condenser flow. Catalogue-based pre-engineered solutions or designed to customer specification. BMS communications protocol available
Armstrong Firepak Vertical In-line
- Applications-Fire-protection of buildings and other built infrastructure.
- Description-The Armstrong Vertical In-line (VIL) FirePak line features the full range of VIL fire pumps with electric motor and controller. All mounted, piped, and wired on a base at the factory. The complete package is designed to fit through a standard door.
- Materials (MOC)-Metal base, piping, pump, and control panel; switchgear; electric motor.
- Configuration-Options available include jockey pump and jockey pump controller. 50 Hz and 60 Hz designs. UL, ULC, and/or FM certification
- Performance range-50 – 1500 USgpm
Armstrong Suction Guides
- Applications-HVAC-system pumping; general purpose pumping; industrial/process pumping (water or glycol based).
- Description-The Armstrong Suction Guides (SG) are multi-function pump fittings that provide a 90° elbow, guide vanes, and an in-line strainer. Suction guides reduce pump installation cost and floor space requirements.
- Materials (MOC)-Cast Iron, ductile iron; grooved, flanged or threaded connections
- Performance range-Suitable for all Armstrong commercial pumps and pumping systems
- Temperature-230°F (110°C)
- Size-1.5” to 20” (40 mm to 500 mm)
Double Window Sight Glass (PN10, PN16)
Applications:
Industrial facilities, oil refineries, bath soap manufacturing plane, gas industries, petrochemical complex, high viscous process media, building construction, environmental water treatments, synthetics, plastic and resin industries, polymer manufacturing plant, food industries (chocolate, sauce etc.), fertilizer industries etc.
Technical Data :
| Design Std. | As per BS 5352 |
| Testing Std. | As per API 598 |
| End Connection | As per ANSI B16.5 |
| Size | 1/2” to 6” (15 mm to150 mm) |
| Size | 2" to 18", Class 150, 300 |
| Pressure rating | PN10 / PN16 |
| Maximum working pressure | 10 Kg/cm2 |
| Test pressure | 20 Kg/cm2 |
Dimensions
| Size | A | B | C |
| 15 | 153 | 51 | 137 |
| 20 | 153 | 51 | 137 |
| 25 | 153 | 51 | 137 |
| 40 | 178 | 64 | 146 |
| 50 | 190 | 76 | 190 |
| 75 | 229 | 102 | 232 |
| 100 | 299 | 127 | 283 |
| 150 | 406 | 191 | 368 |
All dimensions are in mm.