Armstrong Flo-Trex Valves
- Applications-HVAC-system pumping; general purpose pumping; industrial/ process pumping (water or glycol based).
- Description-The Armstrong Flo-Trex Valves (FTV) are multi-function pump fittings that reduce equipment and installation costs.
- Materials (MOC)-Cast iron, ductile iron; grooved, flanged or threaded connections.
- Performance range-Suitable for all Armstrong commercial pumps.
- Temperature-230 °F (110 °C)
- Size-1.25” to 20” (32 mm to 500 mm)
Description
Benefits & Features
Lower installed cost
- Replacement of long-radius elbows, non-return check valves, globe valves and/ or butterfly valves for reduced material and labor cost.
- Fewer pipe connections, down from six (or more) to three for reduced labor cost.
Related products
Armstrong 4030 End Suctionbase Mounted Pumps
- Applications — HVAC-system pumping; light industrial/ process pumping
- Description — The Armstrong 4030 horizontal end-suction (ES) pumps are engineered to substantially reduce cost over competitor designs across installation, operation, and lifetime maintenance. High-efficiency NEMA-premium motors ensure low energy consumption and cost.
- Materials (MOC) — Cast iron, ductile iron, or bronze casing, Cast iron or bronze impeller
- Configuration Inside — single spring mechanical seal.
- Performance range — Up to 5,000 USgpm (315 L/s) flow; up to 600 ft (180 m) head
- Temperature — 250°F (121°C)
- Power Range — 0.33 hp to 300 hp (0.25 kW to 200 kW)
- Size — 1" to 8” (25 mm to 200 mm)
Armstrong Air & Dirt Separators
- Applications-Dirt and air removal from hydronic and HVAC systems.
- Description-The Armstrong dirt & air separators (DAS) are designed to eliminate trapped air and suspended dirt particles associated with the start-up and maintenance of hydronic and HVAC systems.
- Materials (MOC)-Carbon steel (shell), stainless steel (coalescing medium), styrene butadiene rubber (gasket)
Armstrong Design Envelope Integrated Pumping System (IPS 4000)
- Applications-Multi-pump control for heated – or chilled – water system optimization in buildings.
- Description-The Design Envelope Integrated Pumping System (IPS 4000) is an advanced multi-zone control that directly integrates with pumping units to optimize energy performance, system handling, and installation.
- Materials (MOC)-Enclosure, circuitry, software
- Configuration-Integrates seamlessly with Armstrong Design Envelope pumps in a headered configuration.
- Performance range-Up to 8 pumps, 16 zones (variable primary, secondary or tertiary) and 8 flow sensitive equipment (variable primary) IPS 4001w / IPS 4501w for up to 3 pumps, 3 zones and 3 flow sensitive equipment IPS 4002w / IPS 4502w for up to 4 pumps, 6 zones and 4 flow sensitive equipment IPS 4003w / IPS 4503w for up to 6 pumps, 12 zones and 6 flow sensitive equipment IPS 4004w / IPS 4504w for up to 8 pumps, 16 zones and 8 flow sensitive equipment
- Power Range-No limitations in system size and capacity.
- Size-No limitations in system size.
Armstrong Firepak Vertical In-line
- Applications-Fire-protection of buildings and other built infrastructure.
- Description-The Armstrong Vertical In-line (VIL) FirePak line features the full range of VIL fire pumps with electric motor and controller. All mounted, piped, and wired on a base at the factory. The complete package is designed to fit through a standard door.
- Materials (MOC)-Metal base, piping, pump, and control panel; switchgear; electric motor.
- Configuration-Options available include jockey pump and jockey pump controller. 50 Hz and 60 Hz designs. UL, ULC, and/or FM certification
- Performance range-50 – 1500 USgpm
Armstrong Vortex Air Separators
- Applications-Air removal from hydronic and HVAC systems – air can get trapped during initial fill, during routine equipment maintenance (including pressure upkeep), and due to the use of cooling towers.
- Description-The Armstrong vortex air separators create a vortex or whirlpool action, sending the heavier air-free water to the outer portion of the tank, and allowing the lighter air-entrained water mixture to move into the lower-velocity center. At the center of the vortex the air is released from the water, forms bubbles and exits through an air vent or compression tank installed above it.
- Materials (MOC)-Cast iron or fabricated steel (shell), stainless steel mesh (strainer)
Double Window Sight Glass (PN10, PN16)
Applications:
Industrial facilities, oil refineries, bath soap manufacturing plane, gas industries, petrochemical complex, high viscous process media, building construction, environmental water treatments, synthetics, plastic and resin industries, polymer manufacturing plant, food industries (chocolate, sauce etc.), fertilizer industries etc.Technical Data :
| Design Std. | As per BS 5352 |
| Testing Std. | As per API 598 |
| End Connection | As per ANSI B16.5 |
| Size | 1/2” to 6” (15 mm to150 mm) |
| Size | 2" to 18", Class 150, 300 |
| Pressure rating | PN10 / PN16 |
| Maximum working pressure | 10 Kg/cm2 |
| Test pressure | 20 Kg/cm2 |
Dimensions
| Size | A | B | C |
| 15 | 153 | 51 | 137 |
| 20 | 153 | 51 | 137 |
| 25 | 153 | 51 | 137 |
| 40 | 178 | 64 | 146 |
| 50 | 190 | 76 | 190 |
| 75 | 229 | 102 | 232 |
| 100 | 299 | 127 | 283 |
| 150 | 406 | 191 | 368 |
All dimensions are in mm.
Full View Sight Glass (PN10)
Applications:
Industrial facilities, oil refineries, bath soap manufacturing plane, gas industries, petrochemical complex, high viscous process media, building construction, environmental water treatments, synthetics, plastic and resin industries, polymer manufacturing plant, food industries (chocolate, sauce etc.), fertilizer industries etc.Technical Data :
| Design Std. | As per BS 5352 |
| Testing Std. | As per API 598 |
| End Connection | As per ANSI B16.5 |
| Size | ½” to 4” (15 mm to100 mm) |
| Pressure rating | PN10 |
| Maximum working pressure | 10 Kg/cm2 |
| Test pressure | 15 Kg/cm2 |
Dimensions
| Size | A | B | C |
| 15 | 153 | 51 | 137 |
| 20 | 153 | 51 | 137 |
| 25 | 153 | 51 | 137 |
| 40 | 178 | 64 | 146 |
| 50 | 190 | 76 | 190 |
| 75 | 229 | 102 | 132 |
| 100 | 299 | 127 | 283 |
All dimensions are in mm.
POT-BASKET TYPE STRAINER (ANSI 150#, 300#)
Applications:
Strainer can be used in liquid as well as gas line, Regulator and valve protection, steam traps protections, flow meter and pump protections, heat exchanger and refrigeration set protection, Suitable for Hazardous environments. Y-Strainers and pot basket type strainers is a device for mechanically removing unwanted solids from liquid, gas or steam lines by means of a perforated or wire mesh straining element. Where the amount of material to be removed from the flow is relatively small, resulting in long intervals between screen cleanings, the strainer screen is manually cleaned by shutting down the line and removing the strainer cap.Technical Data :
| Design Std. | As per ASME B16.34 |
| Testing Std. | As per API 598 |
| End Connection | Flanged Drill as per ANSI B16.5 |
| Material | Body : IS 2062, Seal : NBR / PTFE / Graphite + SS, Mesh : SS |
| Shell Wall Thickness | As per ANSI B16.34 |
| Size | 2" to 18", Class 150, 300 |
Dimensions 150#
| Size | F/F | A | B |
| 50 | 320 | 190 | 285 |
| 80 | 360 | 200 | 320 |
| 100 | 400 | 210 | 360 |
| 125 | 460 | 230 | 430 |
| 150 | 510 | 240 | 430 |
| 200 | 560 | 280 | 530 |
| 250 | 810 | 420 | 635 |
| 300 | 890 | 430 | 715 |
Dimensions 300#
| Size | F/F | A | B |
| 50 | 380 | 200 | 305 |
| 80 | 420 | 235 | 400 |
| 100 | 475 | 260 | 405 |
| 125 | 510 | 275 | 435 |
| 150 | 620 | 295 | 490 |
| 200 | 630 | 345 | 560 |
| 250 | 900 | 390 | 690 |
| 300 | 1000 | 440 | 770 |
All dimensions are in mm.