Adept Domestic Water Meter DWM – Ultrasonic Water Meter
Ideal Product for Smart City Water Utilities
Introduction
Ultrasonic Water Meter is a device used to measure the velocity of flow by using the principle of ultrasound. It can measure the average velocity along the path of an emitted beam of ultrasound by averaging the difference in measured transit time between the pulses of ultrasound propagating into and against the direction of the flow. The flow measurement is based on an acoustic wave time of flight principle. The Flowmeter body is equipped with 2 ultrasonic transducers facing 2 acoustic reflectors.
IoT Ready
DWM supports IoT ready wireless communication interfaces which are suitable for any type of installation environment, e.g. LoRaWAN or NB-IoT. The data transmission frequency is every 24 hours. Wireless Remote Reading Solution offers reliable remote meter reading solutions with accurate measuring. Utilities no longer need to send engineers on site to read the meter manually. With wireless technology, meter data is uploaded to server automatically on each billing date. With this solution, utility save significant expenditure on installation cost, meter reading labour cost and avoid mistakes in the meter reading. This solution is widely used worldwide on various types of meters.
The LoRaWAN and NB-IoT standards are both part of a larger family of technologies known as LPWAN (Low Power Wide Area Networking).
LoRaWAN is an open protocol offered by the LoRa alliance that uses unlicensed spectrum, allowing almost anyone to set up their own networks at a low cost.
NB-IoT is a licensed protocol from the standards organisation 3GPP offered through the licensed RF spectrum, making it available only through established mobile network operators.
Advanced Technology Flow Instrumentation Solutions
Adept is one of the largest manufacturers of Electromagnetic and Ultrasonic Flowmeters in India and has been acquired by Yokogawa Electric Corporation. Yokogawa provides advanced solutions in the areas of measurement, control, and information to customers across a broad range of industries, including energy, chemicals, materials, pharmaceuticals and food. The acquisition will help to leverage the strong presence of Adept in the Indian market with the technological prowess of Yokogawa.
Adept range of Flowmeters is characterised by advanced technology, excellent quality and high reliability to ensure accurate and precise measurement of fluid flow. We have a large manufacturing facility with two factories operational in Pune, India, certified with IMS (Integrated Management System). This is backed by our in-house Design & Development Centre and the Calibration Laboratory certified with ISO/IEC 17025:2017. More than 70,000 Flowmeters supplied by us are operational in over 25 countries across the world, meeting the stringent requirements of different sectors. The reliability of our products and the dependability of our services are evident from repeat orders from our customers. Over 40% of our business comes from existing customers.
Related products
Adept BTU Meter 6430 Measures Energy Flow precisely and conveniently
Measures Energy Flow precisely and conveniently
Introduction
Salient Features










Applications









Product Selection Guide
Parameters | Specifications |
---|
Power supply | 80 – 300 V AC |
Flowmeter input | 4 – 20 mA DC from Flowmeter (Ultrasonic/Electromagnetic/Any other) |
Temparature input | Matched Pair of PT-100 Sensors or PT 1000 sensors , Standard length – 6m |
Display | 2 Line LCD |
Communication | RS 485 (Modbus RTU), BACnet IP (Optional) |
Mounting | Wall Mount |
Accuracy | ± 0.1% of measured value |
Output – Analog | 4 – 20 mA DC |
Output – Contact | Relay (Optional) |
Energy function | Heat/Cool |
Energy display | W, J, BTU, Cal |
Sampling period | 1 sec. |
Environment temp. | Up to 65°C |
Water temp. | 0 to 50°C (Please consult factory for any other liquid.) |
Enclosure class | IP 65 |
FAQ
Adept Electromagnetic Flowmete – MagBP 6440
Introduction
Salient Features








Applications









Product Selection Guide
Parameters | Specifications |
---|---|
Nominal dia (mm) | 10 to 1000 |
Working pressure (kg/cm2) | 10, 16, 25, 40 |
Working temperature | Up to 55°C |
Electrode material | SS 316L Std.* |
Sensor lining | Std. Rubber* |
Display version | Integral/Remote |
Measuring tube material | SS 304 Std.* |
Sensor housing material | Std. CS* |
End connection | Flange/Wafer/Tri-clamp/SMS |
Flange standard | ANSI 150* |
Measuring range | 0.2 to 12 m/sec. Bidirectional |
Accuracy % of measured value | ±0.5% |
Repeatability | ±0.2% of Span |
Display | LCD |
Display units | All standard engineering units in m³, litre, gallon, ft³, imperial gallon |
Output | Pulse* |
Power supply | Battery powered (5 years’ battery life) |
Protection class for sensor | Std. IP 65 Option IP 67/IP 68 for flow tube in remote type |
Protection class for transmitter | IP 67 |
Cable length for remote | Std. 10 m* |
Installation | Inline flanged type |
Adept Electromagnetic Flowmete – EcoMag 6420
Introduction
Salient Features










Applications









Product Selection Guide
Parameters | Specifications |
---|---|
Nominal dia (mm) | 10 to 200 |
Working pressure (kg/cm2) | 5 |
Working temperature | Up to 55°C |
Electrode material | SS 316L Std.* |
Sensor lining | NA |
Display version | Integral/Remote |
Measuring tube material | HDPE |
Sensor housing material | HDPE |
End connection | Flange |
Flange standard | ANSI 150* |
Measuring range | 0.2 to 12 m/sec. Bidirectional |
Accuracy % of measured value | ±1% |
Repeatability | ±0.2% of Span |
Display | 2 line LCD |
Display units | All standard engineering units in m³, litre, gallon, ft³, imperial gallon |
Output | Std. 4 – 20 mA* |
Power supply | 12 – 60 V DC or 80 – 300 V AC/DC Solar powered |
Protection class for sensor | Std. IP 65 Option IP 67/IP 68 for flow tube in remote type |
Protection class for transmitter | IP 67 |
Cable length for remote | Std. 10 m* |
Installation | Inline flanged type |
Adept Electromagnetic Flowmeter MagFlow 6410
Introduction
Salient Features








Applications









Product Selection Guide
Parameters | Specifications |
---|---|
Nominal dia (mm) | 10 to 3000 |
Working pressure (kg/cm2) | 10, 16, 25, 40 |
Working temperature | Integral PTFE – 120°C Remote PTFE – 180°C Others – 70°C |
Electrode material | SS 316L Std.* |
Sensor lining | Std. Rubber* |
Display version | Integral/Remote |
Measuring tube material | SS 304 Std.* |
Sensor housing material | Std. CS* |
End connection | Flange/Wafer/Tri-clamp/SMS |
Flange standard | ANSI 150* |
Measuring range | 0.2 to 12 m/sec. Bidirectional |
Accuracy % of measured value | ±O.5% (±O.2% consult factory) |
Repeatability | ±0.2% of Span |
Display | 2 line LCD |
Display units | All standard engineering units in m3, litre, gallon, ft3, imperial gallon |
Output | Std. 4 – 20 mA* |
Power supply | 12 – 60 V DC or 80 – 300 V AC/DC Solar powered |
Protection class for sensor | Std. IP 65 Option IP 67/IP 68 for flow tube in remote type |
Protection class for transmitter | IP 67 |
Cable length for remote | Std. 10 m* |
Installation | Inline flanged type |
Adept IoT Gateway 5000
Introduction
Specifications








Adept Ultrasonic Flowmeter – UFM 6710
Introduction
Salient Features









Applications









Product Selection Guide
Parameters | Specifications |
---|
Transmitter | |
Power supply | 24 V DC ± 20% 110 V AC ± 15% 240 V AC ± 15% Solar powered |
Velocity | ±12 m/sec. Bidirectional |
Display | 2 lines, 16 characters, LCD with backlight, flow rate, velocity, totaliser |
Units | User configurable English/Metric |
Totaliser | FWD, NET, REV, BATCH (Gallons, ft³, barrels, lbs, m³) |
Output | 4 – 20 mA DC Std.* |
Accuracy | ±1% of reading @ rate > 0.5 m/sec. (Optional ±0.5% of reading) |
Repeatability | 0.2% of Span |
Protection class | IP 65, IP 67 |
Dimensions | 251x190x96 mm |
Weight | < 2.5 kg |
Security | Keypad lockout, access code enabled |
Sensor | |
Suited temp. – Std. | -40°C to 120°C |
Suited temp. – High | -40°C to 250°C |
Pipe size | |
S Sensor | 15 – 80 mm |
M Sensor | 50 – 700 mm |
L Sensor | 400 – 4570 mm |
Dimensions | |
S Sensor | 45x30x30 mm |
M Sensor | 60x45x45 mm |
L Sensor | 80x70x55 mm |
Weight | |
S Sensor | < 0.3 kg |
M Sensor | < 0.5 kg |
L Sensor | < 1.0 kg |
Protection class | IP 65, IP 67, IP 68 |
Cable length | 6 m std. can be extended up to 300 m |
Flexible belts | SS belt according to pipe size |
Portable case | NA |
Adept Ultrasonic Flowmeter – UFM 6720
Introduction
Salient Features









Applications









Parameters | Specifications |
---|
Transmitter | |
Power supply | 3 AAA NiMH built-in battery (12 hours of operation) & 100-240 V AC for the charger |
Velocity | ±12 m/sec. Bidirectional |
Display | 4 lines, 16 characters, LCD with backlight, flow rate, velocity, totaliser |
Units | User configurable English/Metric |
Totaliser | FWD, NET, REV, BATCH (Gallons, ft³, barrels, lbs, m³) |
Output | RS 232 |
Accuracy | ±1% of reading @ rate > 0.5 m/sec. (Optional ±0.5% of reading) |
Repeatability | 0.2% of Span |
Protection class | IP 54 |
Dimensions | 204x90x30 mm |
Weight | < 0.5 kg |
Security | Keypad lockout, access code enabled |
Sensor | |
Suited temp. – Std. | -40°C to 120°C |
Suited temp. – High | -40°C to 250°C |
Pipe size | |
S Sensor | 15 – 80 mm |
M Sensor | 50 – 700 mm |
L Sensor | 400 – 4570 mm |
Dimensions | |
S Sensor | 45x30x30 mm |
M Sensor | 60x45x45 mm |
L Sensor | 80x70x55 mm |
Weight | |
S Sensor | < 0.3 kg |
M Sensor | < 0.5 kg |
L Sensor | < 1.0 kg |
Protection class | IP 65, IP 67, IP 68 |
Cable length | 6 m std. can be extended up to 25 m |
Flexible belts | SS belt according to pipe size |
Portable case | Size – 463x383x103 mm |
Adept Ultrasonic Flowmeter – UFM 6740
Introduction
Salient Features








Applications




Product Selection Guide
Parameters | Specifications |
---|---|
Technical characteristics | Low power consumption, digital process technology with stable piezoelectric sensor |
Accuracy | ±1% of reading (Optional ±0.5%) |
Repeatability | 0.2% of Span |
Display | Total flow, flow rate, velocity, working time & date, signal intensity, quality & battery status |
Output | RS 485, 4 – 20 mA, Pulse for total flow (All outputs need external power supply 24 V DC) |
Communication interface | GSM, RS 485 (Modbus RTU), UART |
Operation | Inside keypad available |
Sampling period | 0.5 sec |
Environment temp. | Up to 65°C |
Water temp. | 5 to 70°C |
Power supply | Li-ion battery, solar powered |
Enclosure class | IP 68 |
Pipe size | DN 40 – 600 |
Flange standard | ANSI, IS, DIN PN, BS |
Pressure transmitter | Range 0-16 kg/cm², IP 68, 1/2″ male threaded, accuracy 0.25% |