Armstrong Design Envelope Compass h Circulators
- Applications-Residential heating and cooling; potable water supply.
- Description-The Armstrong Compass H is an energy-efficient variable speed wet-rotor circulator. Designed to replace existing fixed speed circulators, with popular flange-to-flange dimensions, Compass H can be considered a universal replacement for all circulators in its capacity range.
- Materials (MOC)-Cast iron and stainless steel volutes.
- Configuration-Eight operation modes with patented “Auto” algorithm, four Sensorless modes and three fixed speed modes. 50 Hz and 60 Hz designs
- Performance range-Up to 20 USgpm (1.26 L/s) flow; up to 20 ft (6.1 m) head
- Temperature-Max ambient temp. 40°C; max water temp. 110°C
- Power Range-5 W to 45 W
- Size-1″
Description
Benefits & Features
Lowest installed cost
- Wide performance range (max head 20 ft (6.1m); max flow 20 USgpm (4.54 m3/h))
- Large wiring chamber and front-mounted terminal block for much easier and faster installation compared to any other circulator currently available
Lowest operating cost
- Easy and quick setup of energy-saving features: eight operation modes with patented “Auto” algorithm, 2 Sensorless modes, 2 constant pressure modes and 3 fixed speed modes.
- Design Envelope Intelligent Variable Speed technology, combined with ECM motors, saves 50% or more in operating cost over fixed speed circulators.
Lowest environmental cost
- Design Envelope Intelligent Variable Speed technology, combined with ECM motors, saves 50% or more in electrical energy and related carbon emissions over fixed speed circulators.
Related products
Armstrong 4030 End Suctionbase Mounted Pumps
- Applications — HVAC-system pumping; light industrial/ process pumping
- Description — The Armstrong 4030 horizontal end-suction (ES) pumps are engineered to substantially reduce cost over competitor designs across installation, operation, and lifetime maintenance. High-efficiency NEMA-premium motors ensure low energy consumption and cost.
- Materials (MOC) — Cast iron, ductile iron, or bronze casing, Cast iron or bronze impeller
- Configuration Inside — single spring mechanical seal.
- Performance range — Up to 5,000 USgpm (315 L/s) flow; up to 600 ft (180 m) head
- Temperature — 250°F (121°C)
- Power Range — 0.33 hp to 300 hp (0.25 kW to 200 kW)
- Size — 1" to 8” (25 mm to 200 mm)
Armstrong 4300 vertical in-line pumps
- Applications-HVAC-system pumping; light industrial/ process pumping (water or glycol based)
- Description-The Armstrong 4300 pipe-mounted pumps are designed for space-saving installation, high operating efficiency, and long service life
- Materials(MOC)-Cast, ductile iron or bronze casing, Cast iron or bronze impeller
- Configuration-Outside balanced or inside single spring mechanical seal
- Performance range-Up to 28,000 USgpm (1,800 L/s) Flow; up to 500 ft (150 m) Head
- Temperature-300oF (150oC)
- Power Range-1 hp to 1250 hp (0.75 kW to 900 kW)
- Size-1.5″ to 20” (40 mm to 500 mm)
Armstrong Air & Dirt Separators
- Applications-Dirt and air removal from hydronic and HVAC systems.
- Description-The Armstrong dirt & air separators (DAS) are designed to eliminate trapped air and suspended dirt particles associated with the start-up and maintenance of hydronic and HVAC systems.
- Materials (MOC)-Carbon steel (shell), stainless steel (coalescing medium), styrene butadiene rubber (gasket)
Armstrong Design Envelope 4302 Dualarm Pumps
- Applications-HVAC system pumping; general purpose pumping; industrial/process pumping (water or glycol based) Armstrong Design Envelope Pumps with integrated controllers are OSHPD pre-approved!
- Description-Pipe-mounted 2-pump unit with integrated intelligent controls for space-saving installation, superior energy performance, and full redundancy or parallel-pumping operation. Saves up to 75% in energy over comparable traditional constant speed or variable frequency operated pump installations.
- Materials (MOC)-Cast iron or ductile iron casing, Cast iron or bronze impeller, Sintered silicon carbide mechanical seal
- Configuration-On-board Intelligent Variable Speed controls with Sensorless or Parallel Sensorless control. Controls enclosure UL type 12 or UL type 4X (outdoor applications). Available with NEMA premium motors. Outside balanced or inside single spring mechanical seal
- Performance range-Up to 1250 USgpm flow and 250 ft head (80 L/s, 76 m)
- Temperature-250°F (121°C)
- Power Range-0.33 hp to 75 hp (0.25 kW to 55 kW)
- Size –1″ to 8” (25 mm to 200 mm)
Armstrong Design Envelope Chilled-Water Integrated Plant Package
- Applications-Commercial and industrial chilled-water cooling systems.
- Description-The Armstrong Chilled-Water Integrated Plant Package combines all the equipment needed to deliver chilled water to medium to large size buildings at superior energy efficiency. The factory-assembled plant includes pumps, integrated controls, water-cooled chillers and the requisite instrumentation, valves and sensors. IPP complies with all ASHRAE 189.1 requirements and exceeds ASHRAE 90.1.
- Configuration-Variable primary with variable condenser flow. Catalogue-based pre-engineered solutions or designed to customer specification. BMS communications protocol available
Armstrong Design Envelope Intelligent Fluid Management System
- Applications-Commercial or industrial closed-loop systems, including HVAC chilled-water systems, boiler systems, cooling tower systems, or process water loops.
- Description-The Armstrong Intelligent Fluid Management System (iFMS) integrates superior pump- and control technology into a single pumping solution yielding both compact and carefree installation as well as superior energy performance. iFMS is ideally suited for partial or all variable speed chilled-water plant applications (variable primary flow, variable secondary flow, variable condenser water flow). In combination with Parallel Sensorless control iFMS saves 30% or more in energy over any other parallel pumping configuration available today.
- Configuration-Up to 4 pumps in one unit. Catalogue-based pre-engineered solutions or designed to customer specification. Integrated control system (IPS 4000, IPC 11550) or connecting to chiller plant/BMS control. Optional single point power panel
Armstrong Expansion Tanks
- Applications-Pressure stabilization in water based mechanical systems such as booster installations, boiler systems, and chiller plants
- Description-Armstrong Expansion Tanks are designed to reduce tank sizes by up to 80% over standard designs. Expansion tanks use compressed air to maintain system pressures by accepting and expelling the changing volume of water as it heats and cools. Diaphragm or bladder tank designs isolate the expanded water from the pressure controlling air cushion – which is pre-charged at the factory and can be adjusted in the field to meet final system requirements
- Materials (MOC)-Carbon steel (shell), heavy duty Butyl (diaphragm)
- Performance range-AET plain steel expansion tanks: 15 to 525 USgpm flow. AX diaphragm expansion tanks: 8 to 211 USgpm flow. Type L bladder type expansion tanks: 10 to 1056 USgpm flow.
Armstrong Vortex Air Separators
- Applications-Air removal from hydronic and HVAC systems – air can get trapped during initial fill, during routine equipment maintenance (including pressure upkeep), and due to the use of cooling towers.
- Description-The Armstrong vortex air separators create a vortex or whirlpool action, sending the heavier air-free water to the outer portion of the tank, and allowing the lighter air-entrained water mixture to move into the lower-velocity center. At the center of the vortex the air is released from the water, forms bubbles and exits through an air vent or compression tank installed above it.
- Materials (MOC)-Cast iron or fabricated steel (shell), stainless steel mesh (strainer)