Adept BTU Meter 6430 Measures Energy Flow precisely and conveniently
Measures Energy Flow precisely and conveniently
Introduction
BTU/Heat Meter is designed to measure the rate of thermal energy flow and total energy consumption in liquid heating and cooling applications. To know precisely the amount of energy extracted, rely on Adept BTU Meter. It measures parameters such as flow of the medium, and inlet & outlet temperatures. Net Heat Transfer is automatically calculated by using this data of temperature difference.
Salient Features










Applications









Product Selection Guide
Parameters | Specifications |
---|
Power supply | 80 – 300 V AC |
Flowmeter input | 4 – 20 mA DC from Flowmeter (Ultrasonic/Electromagnetic/Any other) |
Temparature input | Matched Pair of PT-100 Sensors or PT 1000 sensors , Standard length – 6m |
Display | 2 Line LCD |
Communication | RS 485 (Modbus RTU), BACnet IP (Optional) |
Mounting | Wall Mount |
Accuracy | ± 0.1% of measured value |
Output – Analog | 4 – 20 mA DC |
Output – Contact | Relay (Optional) |
Energy function | Heat/Cool |
Energy display | W, J, BTU, Cal |
Sampling period | 1 sec. |
Environment temp. | Up to 65°C |
Water temp. | 0 to 50°C (Please consult factory for any other liquid.) |
Enclosure class | IP 65 |
FAQ
What is BTU Meter?
BTU meters measure the energy content of liquid flow in British thermal units (BTU), a basic measure of thermal energy. BTU meters are used in chilled water systems for both commercial and industrial and office buildings. These meters are used to bill users for energy usage.
Advanced Technology Flow Instrumentation Solutions
Adept is one of the largest manufacturers of Electromagnetic and Ultrasonic Flowmeters in India and has been acquired by Yokogawa Electric Corporation. Yokogawa provides advanced solutions in the areas of measurement, control, and information to customers across a broad range of industries, including energy, chemicals, materials, pharmaceuticals and food. The acquisition will help to leverage the strong presence of Adept in the Indian market with the technological prowess of Yokogawa.
Adept range of Flowmeters is characterised by advanced technology, excellent quality and high reliability to ensure accurate and precise measurement of fluid flow. We have a large manufacturing facility with two factories operational in Pune, India, certified with IMS (Integrated Management System). This is backed by our in-house Design & Development Centre and the Calibration Laboratory certified with ISO/IEC 17025:2017. More than 70,000 Flowmeters supplied by us are operational in over 25 countries across the world, meeting the stringent requirements of different sectors. The reliability of our products and the dependability of our services are evident from repeat orders from our customers. Over 40% of our business comes from existing customers.
Related products
Adept Domestic Water Meter DWM – Ultrasonic Water Meter
Ideal Product for Smart City Water Utilities
Introduction
IoT Ready
Adept Electromagnetic Flowmete – MagBP 6440
Introduction
Salient Features








Applications









Product Selection Guide
Parameters | Specifications |
---|---|
Nominal dia (mm) | 10 to 1000 |
Working pressure (kg/cm2) | 10, 16, 25, 40 |
Working temperature | Up to 55°C |
Electrode material | SS 316L Std.* |
Sensor lining | Std. Rubber* |
Display version | Integral/Remote |
Measuring tube material | SS 304 Std.* |
Sensor housing material | Std. CS* |
End connection | Flange/Wafer/Tri-clamp/SMS |
Flange standard | ANSI 150* |
Measuring range | 0.2 to 12 m/sec. Bidirectional |
Accuracy % of measured value | ±0.5% |
Repeatability | ±0.2% of Span |
Display | LCD |
Display units | All standard engineering units in m³, litre, gallon, ft³, imperial gallon |
Output | Pulse* |
Power supply | Battery powered (5 years’ battery life) |
Protection class for sensor | Std. IP 65 Option IP 67/IP 68 for flow tube in remote type |
Protection class for transmitter | IP 67 |
Cable length for remote | Std. 10 m* |
Installation | Inline flanged type |
Adept Electromagnetic Flowmete – MagFlow 6415
Introduction
Salient Features








Applications









Product Selection Guide
Parameters | MagFlow 6415 |
---|---|
Nominal dia (mm) | 10 to 3000 |
Working pressure (kg/cm2) | 10, 16, 25, 40 |
Working temperature | Integral PTFE – 120°C Remote PTFE – 180°C Others – 70°C |
Electrode material | SS 316L Std.* |
Sensor lining | Std. Rubber* |
Display version | Integral/Remote |
Measuring tube material | SS 304 Std.* |
Sensor housing material | Std. CS* |
End connection | Flange/Wafer/Tri-clamp/SMS |
Flange standard | ANSI 150* |
Measuring range | 0.2 to 12 m/sec. Bidirectional |
Accuracy % of measured value | ±O.5% (±O.2% consult factory) |
Repeatability | ±0.2% of Span |
Display | Graphic LCD |
Display units | All standard engineering units in m³, litre, gallon, ft³, imperial gallon |
Output | Std. 4 – 20 mA, Pulse, RS 485 |
Dual power supply | 12 – 60 V DC or 80 – 300 V AC/DC |
Protection class for sensor | Std. IP 67 Option IP 68 for flow tube in remote type |
Protection class for transmitter | IP 67 |
Cable length for remote | Std. 10 m* |
Grounding | Built-in electrode |
Installation | Inline |
Adept Electromagnetic Flowmete – EcoMag 6420
Introduction
Salient Features










Applications









Product Selection Guide
Parameters | Specifications |
---|---|
Nominal dia (mm) | 10 to 200 |
Working pressure (kg/cm2) | 5 |
Working temperature | Up to 55°C |
Electrode material | SS 316L Std.* |
Sensor lining | NA |
Display version | Integral/Remote |
Measuring tube material | HDPE |
Sensor housing material | HDPE |
End connection | Flange |
Flange standard | ANSI 150* |
Measuring range | 0.2 to 12 m/sec. Bidirectional |
Accuracy % of measured value | ±1% |
Repeatability | ±0.2% of Span |
Display | 2 line LCD |
Display units | All standard engineering units in m³, litre, gallon, ft³, imperial gallon |
Output | Std. 4 – 20 mA* |
Power supply | 12 – 60 V DC or 80 – 300 V AC/DC Solar powered |
Protection class for sensor | Std. IP 65 Option IP 67/IP 68 for flow tube in remote type |
Protection class for transmitter | IP 67 |
Cable length for remote | Std. 10 m* |
Installation | Inline flanged type |
Adept Electromagnetic Flowmeter – MagProbe 6450
Introduction
Salient Features








Applications




Product Selection Guide
Parameters | Specifications |
---|---|
Nominal dia (mm) | > 100 |
Working pressure (kg/cm2) | 20 |
Working temperature | Up to 120°C |
Electrode material | SS 316L Std.* |
Sensor lining | NA |
Display version | Integral/Remote |
Measuring tube material | SS 316 Std.* |
Sensor housing material | NA |
End connection | NA |
Flange standard | NA |
Measuring range | 0.2 to 12 m/sec. Bidirectional |
Accuracy % of measured value | ±2% |
Repeatability | ±0.2% of Span |
Display | 2 line LCD |
Display units | All standard engineering units in m³, litre, gallon, ft³, imperial gallon |
Output | Std. 4 – 20 mA* |
Power supply | 12 – 60 V DC or 80 – 300 V AC/DC Solar powered |
Protection class for sensor | Std. IP 68 |
Protection class for transmitter | IP 67 |
Cable length for remote | Std. 10 m* |
Installation | Insertion type with use of isolating ball valve assembly on pipeline |
Adept Electromagnetic Flowmeter MagFlow 6410
Introduction
Salient Features








Applications









Product Selection Guide
Parameters | Specifications |
---|---|
Nominal dia (mm) | 10 to 3000 |
Working pressure (kg/cm2) | 10, 16, 25, 40 |
Working temperature | Integral PTFE – 120°C Remote PTFE – 180°C Others – 70°C |
Electrode material | SS 316L Std.* |
Sensor lining | Std. Rubber* |
Display version | Integral/Remote |
Measuring tube material | SS 304 Std.* |
Sensor housing material | Std. CS* |
End connection | Flange/Wafer/Tri-clamp/SMS |
Flange standard | ANSI 150* |
Measuring range | 0.2 to 12 m/sec. Bidirectional |
Accuracy % of measured value | ±O.5% (±O.2% consult factory) |
Repeatability | ±0.2% of Span |
Display | 2 line LCD |
Display units | All standard engineering units in m3, litre, gallon, ft3, imperial gallon |
Output | Std. 4 – 20 mA* |
Power supply | 12 – 60 V DC or 80 – 300 V AC/DC Solar powered |
Protection class for sensor | Std. IP 65 Option IP 67/IP 68 for flow tube in remote type |
Protection class for transmitter | IP 67 |
Cable length for remote | Std. 10 m* |
Installation | Inline flanged type |
Adept IoT Gateway 5000
Introduction
Specifications








Adept Ultrasonic Flowmeter – UFM 6720
Introduction
Salient Features









Applications









Parameters | Specifications |
---|
Transmitter | |
Power supply | 3 AAA NiMH built-in battery (12 hours of operation) & 100-240 V AC for the charger |
Velocity | ±12 m/sec. Bidirectional |
Display | 4 lines, 16 characters, LCD with backlight, flow rate, velocity, totaliser |
Units | User configurable English/Metric |
Totaliser | FWD, NET, REV, BATCH (Gallons, ft³, barrels, lbs, m³) |
Output | RS 232 |
Accuracy | ±1% of reading @ rate > 0.5 m/sec. (Optional ±0.5% of reading) |
Repeatability | 0.2% of Span |
Protection class | IP 54 |
Dimensions | 204x90x30 mm |
Weight | < 0.5 kg |
Security | Keypad lockout, access code enabled |
Sensor | |
Suited temp. – Std. | -40°C to 120°C |
Suited temp. – High | -40°C to 250°C |
Pipe size | |
S Sensor | 15 – 80 mm |
M Sensor | 50 – 700 mm |
L Sensor | 400 – 4570 mm |
Dimensions | |
S Sensor | 45x30x30 mm |
M Sensor | 60x45x45 mm |
L Sensor | 80x70x55 mm |
Weight | |
S Sensor | < 0.3 kg |
M Sensor | < 0.5 kg |
L Sensor | < 1.0 kg |
Protection class | IP 65, IP 67, IP 68 |
Cable length | 6 m std. can be extended up to 25 m |
Flexible belts | SS belt according to pipe size |
Portable case | Size – 463x383x103 mm |