Armstrong Firepak Horizontal Split Case
- Applications-Fire-protection of buildings and other built infrastructure.
- Description-The Horizontal Split-Case (HSC) FirePak offering features the full range of Armstrong HSC fire pumps, electric or diesel-driven, and controller. All mounted, piped, and wired on a base at the factory.
- Materials (MOC)-Metal base, piping, pump, and control panel; switchgear; electric motor/ diesel engine
- Configuration-Optional features include jockey pump, jockey pump controller city by-pass loop, flow meter loop, main relief valve plus waste cone, and diesel fuel tank. 50 Hz and 60 Hz electric versions.
- Performance range-500 – 3000 USgpm
Description
Benefits & Features
Lowest installed cost and smallest footprint
- Factory configured and assembled for up to 30% lower cost and up to 90% less installation time over equivalent separate component supply installation.
- Complete pre-assembled package for eliminating onsite installation waste and motor-pump alignments.
Minimal project and operating risk
- Complete pre-assembled package in accordance with all applicable NFPA codes and standards for carefree site approval.
- Product design, assembly and testing in a controlled ISO 14000 factory environment for trouble-free installation and lifetime performance.
- Single-source responsibility for convenient project and product support.
Related products
Armstrong 4280 Motor Mounted Pumps
- Applications-HVAC-system pumping; light industrial / process pumping.
- Description-The Armstrong 4280 horizontal end-suction pumps are equipped with close-coupled motors to minimize footprint requirements.
- Materials(MOC)-Cast iron, ductile iron, or bronze casing, Cast iron or bronze impeller.
- Configuration-Inside single-spring mechanical seal
- Performance range-Up to 2,000 USgpm (125 L/s) flow; up to 400 f (120 m)
- Temperature-250°F (121°C)
- Power Range-0.33 hp to 60 hp (0.25 kW to 45 kW)
- Size-1" to 6” (25 mm to 150 mm)
Armstrong Air & Dirt Separators
- Applications-Dirt and air removal from hydronic and HVAC systems.
- Description-The Armstrong dirt & air separators (DAS) are designed to eliminate trapped air and suspended dirt particles associated with the start-up and maintenance of hydronic and HVAC systems.
- Materials (MOC)-Carbon steel (shell), stainless steel (coalescing medium), styrene butadiene rubber (gasket)
Armstrong Design Envelope 4302 Dualarm Pumps
- Applications-HVAC system pumping; general purpose pumping; industrial/process pumping (water or glycol based) Armstrong Design Envelope Pumps with integrated controllers are OSHPD pre-approved!
- Description-Pipe-mounted 2-pump unit with integrated intelligent controls for space-saving installation, superior energy performance, and full redundancy or parallel-pumping operation. Saves up to 75% in energy over comparable traditional constant speed or variable frequency operated pump installations.
- Materials (MOC)-Cast iron or ductile iron casing, Cast iron or bronze impeller, Sintered silicon carbide mechanical seal
- Configuration-On-board Intelligent Variable Speed controls with Sensorless or Parallel Sensorless control. Controls enclosure UL type 12 or UL type 4X (outdoor applications). Available with NEMA premium motors. Outside balanced or inside single spring mechanical seal
- Performance range-Up to 1250 USgpm flow and 250 ft head (80 L/s, 76 m)
- Temperature-250°F (121°C)
- Power Range-0.33 hp to 75 hp (0.25 kW to 55 kW)
- Size –1″ to 8” (25 mm to 200 mm)
Armstrong Design Envelope 6800 Vertical Multistage Boosters
- Applications-New and retrofit water boosting installations in mid to large size residential, commercial, or industrial settings (such as apartment buildings, office towers, hospitals, hotels, schools, water treatment plants, factories, etc.)
- Description-The Armstrong Design Envelope 6800 Boosters are fully assembled, programmed, integrated and factory-tested turn-key booster systems. They are equipped with vertical multistage pumps and come in arrangements of 2 to 5 pumps. The integrated controls allow for superior performance and energy efficiency across broad operating envelopes. Most suitable for applications where energy consumption and low maintenance are critical, installation space comes at a premium, and occupant comfort is a high priority.
- Materials (MOC)-Piping: stainless steel 304
- Configuration-The 6800 Booster range offers enhanced features, such as improved touchscreens, more performance envelopes, an easy-to-use selection software, and onboard energy and flow readings both present and historic. For the full improved feature set please refer to the Solution Outline for this product.
- Performance range-Up to 2000 USgpm (450 m3/hr) flow; up to 370 psi (22 bar) pressure
- Power Range-Up to 250 hp (up to 185 kW)
Armstrong Design Envelope 9521 Integrated Plant Control System (IPC 9521)
- Applications-Automated chiller plant control for optimizing variable primary flow water-cooled chiller plants. The 9521 IPC works in a variable primary configuration and keeps the entire plant including water-cooled chillers, cooling towers, chilled water and condenser pumps running smoothly.
- Description-The Armstrong Integrated Water-Cooled Chiller Plant Control System (IPC) boosts energy efficiencies of new and existing chiller plant installations to leading class levels. The IPC 9521 works with all variable primary configurations, keeping the entire plant – including water-cooled chillers, cooling towers, chilled water and condenser pumps – running at optimum performance and occupant comfort.
- Configuration-Integrates with all brands of chillers, pumps, and automation systems. Installs directly with chiller plant equipment. If preferred, the IPC connects seamlessly with any central building automation system (BAS) maintaining full control of the chilled water plant through the BAS
- Performance range-Controls up to five chillers, five cooling towers and five pumps. No limitations in plant size and cooling capacity.
- Power Range-No limitations in plant cooling capacity
Armstrong Design Envelope Integrated Pumping System (IPS 4000)
- Applications-Multi-pump control for heated – or chilled – water system optimization in buildings.
- Description-The Design Envelope Integrated Pumping System (IPS 4000) is an advanced multi-zone control that directly integrates with pumping units to optimize energy performance, system handling, and installation.
- Materials (MOC)-Enclosure, circuitry, software
- Configuration-Integrates seamlessly with Armstrong Design Envelope pumps in a headered configuration.
- Performance range-Up to 8 pumps, 16 zones (variable primary, secondary or tertiary) and 8 flow sensitive equipment (variable primary) IPS 4001w / IPS 4501w for up to 3 pumps, 3 zones and 3 flow sensitive equipment IPS 4002w / IPS 4502w for up to 4 pumps, 6 zones and 4 flow sensitive equipment IPS 4003w / IPS 4503w for up to 6 pumps, 12 zones and 6 flow sensitive equipment IPS 4004w / IPS 4504w for up to 8 pumps, 16 zones and 8 flow sensitive equipment
- Power Range-No limitations in system size and capacity.
- Size-No limitations in system size.
Armstrong Firepak Vertical In-line
- Applications-Fire-protection of buildings and other built infrastructure.
- Description-The Armstrong Vertical In-line (VIL) FirePak line features the full range of VIL fire pumps with electric motor and controller. All mounted, piped, and wired on a base at the factory. The complete package is designed to fit through a standard door.
- Materials (MOC)-Metal base, piping, pump, and control panel; switchgear; electric motor.
- Configuration-Options available include jockey pump and jockey pump controller. 50 Hz and 60 Hz designs. UL, ULC, and/or FM certification
- Performance range-50 – 1500 USgpm
Armstrong Vortex Air Separators
- Applications-Air removal from hydronic and HVAC systems – air can get trapped during initial fill, during routine equipment maintenance (including pressure upkeep), and due to the use of cooling towers.
- Description-The Armstrong vortex air separators create a vortex or whirlpool action, sending the heavier air-free water to the outer portion of the tank, and allowing the lighter air-entrained water mixture to move into the lower-velocity center. At the center of the vortex the air is released from the water, forms bubbles and exits through an air vent or compression tank installed above it.
- Materials (MOC)-Cast iron or fabricated steel (shell), stainless steel mesh (strainer)