Armstrong Design Envelope Chilled-Water Integrated Plant Package
- Applications-Commercial and industrial chilled-water cooling systems.
- Description-The Armstrong Chilled-Water Integrated Plant Package combines all the equipment needed to deliver chilled water to medium to large size buildings at superior energy efficiency. The factory-assembled plant includes pumps, integrated controls, water-cooled chillers and the requisite instrumentation, valves and sensors. IPP complies with all ASHRAE 189.1 requirements and exceeds ASHRAE 90.1.
- Configuration-Variable primary with variable condenser flow. Catalogue-based pre-engineered solutions or designed to customer specification. BMS communications protocol available
Description
Benefits & Features
Lowest installed cost
- Factory-designed, built and tested plant package for fast and easy installation and up to 25% lower cost at commissioning compared to equivalent separate component supply installation
Lowest operating cost
- Complete pre-assembled unit – combined with perfect component match-up and tuning – for up to 50% in energy savings (.5 kW/ton) over conventional chilled water plant installations
Lowest environmental cost
- Optimum, demand-based plant performance for up to 50% higher energy efficiency (.5 kW/ton) over conventional chilled water plant installations.
- Optimum, demand-based plant performance for up to 50% lower carbon (greenhouse gas) emissions (avoided electricity generation)
Lowest project and operating risk
- Product design, assembly and testing in a controlled ISO 14000 factory environment for trouble-free installation and sustained lifetime performance.
- Free first-year ECO*Pulse™ HVAC health management (includes predictive maintenance) for reduced plant failure and downtime
- Single-source responsibility for convenient project and product support
Related products
Armstrong 4380 vertical in-line pumps
- Applications-HVAC-system pumping; light industrial/ process pumping. (water or glycol based)
- Description-The Armstrong 4380 pipe-mounted pumps are designed for space-saving installation and long service life.
- Materials(MOC)-Cast iron or ductile iron casing, Silicon sintered carbide mechanical seal, Cast iron or bronze impeller.
- Configuration-Inside single-spring mechanical seal.
- Performance range-Up to 2,500 USgpm (160 L/s) flow; up to 300 ft (90 m) head
- Temperature-250°F (121°C)
- Power Range-0.33 hp to 60 hp (0.25 kW to 45 kW)
- Size-1.5″ to 8″ (40 mm to 200 mm)
Armstrong Air & Dirt Separators
- Applications-Dirt and air removal from hydronic and HVAC systems.
- Description-The Armstrong dirt & air separators (DAS) are designed to eliminate trapped air and suspended dirt particles associated with the start-up and maintenance of hydronic and HVAC systems.
- Materials (MOC)-Carbon steel (shell), stainless steel (coalescing medium), styrene butadiene rubber (gasket)
Armstrong Design Envelope 4300 Pumps
- Applications-HVAC-system pumping and control; general purpose pumping; industrial/process pumping and control. (water or glycol based)
- Description-Pipe-mounted UL 778 pumping unit with integrated intelligent controls for space-saving installation and superior energy performance. Saves up to 75% in energy over comparable traditional constant speed or variable frequency operated pump installations. Remote services through internet to enhance reliability and sustain optimal performance over life of pumps.
- Materials(MOC)-Ductile iron e-coated casing, Stainless steel impeller, Sintered silicon carbide mechanical seal
- Configuration-On-board Intelligent Variable Speed controls with Sensorless control. Split-coupling design and outside balanced or inside single spring mechanical seal. Controls enclosure UL type 12 or UL type 4X for outdoor applications. 0.33-50hp range standard with DEPM motors that reduce losses by more than 20% over NEMA Premium efficiency. Network capable for remote performance management services.
- Performance range-25 to 25,000 USgpm (1.5 to 1500 L/s) flow; 10 to 300 ft (3 to 90 m) head (composite curves available)
- Temperature-300oF (150oC)
- Power Range-0.33 hp to 1250 hp (0.25 kW to 900 kW)
- Size-1″ to 20″ (25 mm to 500 mm)
Armstrong Design Envelope 4302 Dualarm Pumps
- Applications-HVAC system pumping; general purpose pumping; industrial/process pumping (water or glycol based) Armstrong Design Envelope Pumps with integrated controllers are OSHPD pre-approved!
- Description-Pipe-mounted 2-pump unit with integrated intelligent controls for space-saving installation, superior energy performance, and full redundancy or parallel-pumping operation. Saves up to 75% in energy over comparable traditional constant speed or variable frequency operated pump installations.
- Materials (MOC)-Cast iron or ductile iron casing, Cast iron or bronze impeller, Sintered silicon carbide mechanical seal
- Configuration-On-board Intelligent Variable Speed controls with Sensorless or Parallel Sensorless control. Controls enclosure UL type 12 or UL type 4X (outdoor applications). Available with NEMA premium motors. Outside balanced or inside single spring mechanical seal
- Performance range-Up to 1250 USgpm flow and 250 ft head (80 L/s, 76 m)
- Temperature-250°F (121°C)
- Power Range-0.33 hp to 75 hp (0.25 kW to 55 kW)
- Size –1″ to 8” (25 mm to 200 mm)
Armstrong Design Envelope 6800 Vertical Multistage Boosters
- Applications-New and retrofit water boosting installations in mid to large size residential, commercial, or industrial settings (such as apartment buildings, office towers, hospitals, hotels, schools, water treatment plants, factories, etc.)
- Description-The Armstrong Design Envelope 6800 Boosters are fully assembled, programmed, integrated and factory-tested turn-key booster systems. They are equipped with vertical multistage pumps and come in arrangements of 2 to 5 pumps. The integrated controls allow for superior performance and energy efficiency across broad operating envelopes. Most suitable for applications where energy consumption and low maintenance are critical, installation space comes at a premium, and occupant comfort is a high priority.
- Materials (MOC)-Piping: stainless steel 304
- Configuration-The 6800 Booster range offers enhanced features, such as improved touchscreens, more performance envelopes, an easy-to-use selection software, and onboard energy and flow readings both present and historic. For the full improved feature set please refer to the Solution Outline for this product.
- Performance range-Up to 2000 USgpm (450 m3/hr) flow; up to 370 psi (22 bar) pressure
- Power Range-Up to 250 hp (up to 185 kW)
Armstrong Design Envelope Integrated Pumping System (IPS 4000)
- Applications-Multi-pump control for heated – or chilled – water system optimization in buildings.
- Description-The Design Envelope Integrated Pumping System (IPS 4000) is an advanced multi-zone control that directly integrates with pumping units to optimize energy performance, system handling, and installation.
- Materials (MOC)-Enclosure, circuitry, software
- Configuration-Integrates seamlessly with Armstrong Design Envelope pumps in a headered configuration.
- Performance range-Up to 8 pumps, 16 zones (variable primary, secondary or tertiary) and 8 flow sensitive equipment (variable primary) IPS 4001w / IPS 4501w for up to 3 pumps, 3 zones and 3 flow sensitive equipment IPS 4002w / IPS 4502w for up to 4 pumps, 6 zones and 4 flow sensitive equipment IPS 4003w / IPS 4503w for up to 6 pumps, 12 zones and 6 flow sensitive equipment IPS 4004w / IPS 4504w for up to 8 pumps, 16 zones and 8 flow sensitive equipment
- Power Range-No limitations in system size and capacity.
- Size-No limitations in system size.
Armstrong Design Envelope Intelligent Fluid Management System
- Applications-Commercial or industrial closed-loop systems, including HVAC chilled-water systems, boiler systems, cooling tower systems, or process water loops.
- Description-The Armstrong Intelligent Fluid Management System (iFMS) integrates superior pump- and control technology into a single pumping solution yielding both compact and carefree installation as well as superior energy performance. iFMS is ideally suited for partial or all variable speed chilled-water plant applications (variable primary flow, variable secondary flow, variable condenser water flow). In combination with Parallel Sensorless control iFMS saves 30% or more in energy over any other parallel pumping configuration available today.
- Configuration-Up to 4 pumps in one unit. Catalogue-based pre-engineered solutions or designed to customer specification. Integrated control system (IPS 4000, IPC 11550) or connecting to chiller plant/BMS control. Optional single point power panel
Armstrong Firepak Vertical In-line
- Applications-Fire-protection of buildings and other built infrastructure.
- Description-The Armstrong Vertical In-line (VIL) FirePak line features the full range of VIL fire pumps with electric motor and controller. All mounted, piped, and wired on a base at the factory. The complete package is designed to fit through a standard door.
- Materials (MOC)-Metal base, piping, pump, and control panel; switchgear; electric motor.
- Configuration-Options available include jockey pump and jockey pump controller. 50 Hz and 60 Hz designs. UL, ULC, and/or FM certification
- Performance range-50 – 1500 USgpm